Skip to main content
Guide
Helix Cloud runs one writer and two readers behind a routing gateway. Applications send the same dynamic operation-tree request used in local and embedded modes, or a Cypher or SQL statement to POST /v2/cypher or POST /v2/sql, which the gateway routes by whether the statement writes.

Request flow

A read goes to the writer only when it sets X-Helix-Require-Writer: true. With no reader available, a read fails with 503 backend_unavailable rather than moving to the writer. See Architecture.

Connect and send a request

Copy the endpoint and database ID from the database’s Connect panel in the dashboard, and create an API key. Send the database ID in X-Helix-Database-Id with every request; without it, a shared (GA) gateway returns 400 tenant_id_required, and a dedicated cluster returns 403 forbidden for a database key. The TypeScript SDK (@helix-db/helix-db 3.2.0 and later) sends the header after withDatabaseId:
The released Rust (3.0.0), Python (0.3.4), and Go (v0.3.1) SDKs do not send the header; from those languages, call the HTTP API directly:
An endpoint that serves a single database rejects the header with 400 tenant_id_not_allowed; omit it there. request.json holds the operation-tree body the SDKs send:
JSON
Keep API keys in secrets management, not source control. The JSON example is the request body sent to POST /v2/query. The same lookup as a Cypher statement goes in the query field of a POST /v2/cypher body:
query_name is optional diagnostic metadata that names the query in query insights. The query itself remains entirely inside the request; there is no route deployment step.

Routing controls

SDK request builders expose advanced server-only controls, sent as headers:
  • Send a read to the writer (X-Helix-Require-Writer: true) to read your own committed writes immediately. See read-after-write.
  • Warm caches without returning a result (X-Helix-Warm: true). See Query warming.
  • Wait for durability (X-Helix-Await-Durable). Helix Cloud writes always wait, and a write that sends false returns 400 invalid_request.
Embedded clients reject these controls because they describe distributed routing.

Query warming

Send an ordinary read request with X-Helix-Warm: true to execute it on every eligible database backend without returning the query result. The gateway returns 204 No Content after at least one backend succeeds, including when another target fails. If every target fails, the normal deterministic error response is returned. Warming targets every database process that is currently serving, the writer included. Add X-Helix-Require-Writer: true to target only the writer. Authentication, request rate limits, retries, and the normal query timeout still apply before and during fanout. Warming populates the storage and vector caches touched by the read; it does not create a separate result cache. X-Helix-Warm: true or 1 enables warming; false or 0 leaves the request on the ordinary query path. Invalid values and warm write requests return 400 Bad Request; writes are rejected before backend execution. A managed cluster with no eligible warming target returns 503 Service Unavailable.

Monitor queries

Give each query a stable query_name. Query insights group runs by name; unnamed queries group only with identical query JSON, so inlining different values splits them into separate entries. Users signed in to the Helix Cloud MCP can read the same data with helix_get_query_insights, helix_get_query_latency (latency percentiles, including p99), helix_list_query_recommendations, and helix_get_database_usage (hourly or daily read and write counts).

Next steps

Architecture

Understand readers, the writer, storage, and routing.

Guarantees

Review transaction and durability behavior.

Security

Handle authentication and tenant isolation.

Cloud CLI workflow

Authenticate and connect a project.